r2950 Saturday 12th July, 2008 at 12:18:58 UTC by Wilbert Pol
[INS8250] Upper four bits of the IER register should always be 0;
[src/mess/machine]ins8250.c

src/mess/machine/ins8250.c
r2949r2950
404404         }
405405         else
406406         {
407            data = ins8250->ier;
407            data = ins8250->ier & 0x0f;
408408            COM_LOG(2,"COM_ier_r",("COM \"%s\" $%02x\n", device->tag, data));
409409            }
410410            break;