Previous 15994 Revisions Next

r2479 Saturday 26th April, 2008 at 14:20:02 UTC by Wilbert Pol
[INS8250] Fixed setting of bit 0 in the iir register. Added partial support for writes to the line status register.
[src/mess/machine]ins8250.c

src/mess/machine/ins8250.c
r2478r2479
190190   ins8250_t   *ins8250 = get_safe_token(device);
191191   int state;
192192
193   /* disable int output? */
194   if ((ins8250->mcr & 0x08) == 0)
195      return;
196
197193   /* if any bits are set and are enabled */
198194   if (((ins8250->int_pending&ins8250->ier) & 0x0f) != 0)
199195   {
r2478r2479
201197
202198      /* set int */
203199      state = 1;
204
205200      ins8250_setup_iir(device);
206201
207202      /* int pending */
208      ins8250->iir |= 0x01;
203      ins8250->iir &= ~0x01;
209204   }
210205   else
211206   {
r2478r2479
213208      state = 0;
214209
215210      /* no ints pending */
216      ins8250->iir &= ~0x01;
211      ins8250->iir |= 0x01;
217212      /* priority level */
218213      ins8250->iir &= ~(0x04|0x02);
219214   }
220215
221
222   /* set or clear the int */
223   if (ins8250->interface->interrupt)
224      ins8250->interface->interrupt(device, state);
216   if ( ins8250->mcr & 0x08 ) {
217      /* set or clear the int */
218      if (ins8250->interface->interrupt)
219         ins8250->interface->interrupt(device, state);
220   }
225221}
226222
227223
r2478r2479
309305            ins8250->interface->handshake_out(device,data);
310306            break;
311307      case 5:
308         /*
309           This register can be written, but if you write a 1 bit into any of
310           bits 5 - 0, you could cause an interrupt if the appropriate IER bit
311           is set.
312         */
313         COM_LOG(1,"COM_lsr_w",("COM $%02x\n", data ));
314
315         ins8250->lsr = data;
316
317         switch( ins8250->lsr & 0x21 ) {
318         case 0x01:
319            ins8250_trigger_int( device, COM_INT_PENDING_RECEIVED_DATA_AVAILABLE );
320            break;
321         case 0x20:
322            ins8250_trigger_int( device, COM_INT_PENDING_TRANSMITTER_HOLDING_REGISTER_EMPTY );
323            break;
324         case 0x21:
325            ins8250_trigger_int( device, COM_INT_PENDING_RECEIVED_DATA_AVAILABLE | COM_INT_PENDING_TRANSMITTER_HOLDING_REGISTER_EMPTY );
326            break;
327         }
312328         break;
313329      case 6:
314330         break;

Previous 15994 Revisions Next