src/mess/machine/ins8250.c
| r2478 | r2479 | |
| 190 | 190 | ins8250_t *ins8250 = get_safe_token(device); |
| 191 | 191 | int state; |
| 192 | 192 | |
| 193 | | /* disable int output? */ |
| 194 | | if ((ins8250->mcr & 0x08) == 0) |
| 195 | | return; |
| 196 | | |
| 197 | 193 | /* if any bits are set and are enabled */ |
| 198 | 194 | if (((ins8250->int_pending&ins8250->ier) & 0x0f) != 0) |
| 199 | 195 | { |
| r2478 | r2479 | |
| 201 | 197 | |
| 202 | 198 | /* set int */ |
| 203 | 199 | state = 1; |
| 204 | | |
| 205 | 200 | ins8250_setup_iir(device); |
| 206 | 201 | |
| 207 | 202 | /* int pending */ |
| 208 | | ins8250->iir |= 0x01; |
| 203 | ins8250->iir &= ~0x01; |
| 209 | 204 | } |
| 210 | 205 | else |
| 211 | 206 | { |
| r2478 | r2479 | |
| 213 | 208 | state = 0; |
| 214 | 209 | |
| 215 | 210 | /* no ints pending */ |
| 216 | | ins8250->iir &= ~0x01; |
| 211 | ins8250->iir |= 0x01; |
| 217 | 212 | /* priority level */ |
| 218 | 213 | ins8250->iir &= ~(0x04|0x02); |
| 219 | 214 | } |
| 220 | 215 | |
| 221 | | |
| 222 | | /* set or clear the int */ |
| 223 | | if (ins8250->interface->interrupt) |
| 224 | | ins8250->interface->interrupt(device, state); |
| 216 | if ( ins8250->mcr & 0x08 ) { |
| 217 | /* set or clear the int */ |
| 218 | if (ins8250->interface->interrupt) |
| 219 | ins8250->interface->interrupt(device, state); |
| 220 | } |
| 225 | 221 | } |
| 226 | 222 | |
| 227 | 223 | |
| r2478 | r2479 | |
| 309 | 305 | ins8250->interface->handshake_out(device,data); |
| 310 | 306 | break; |
| 311 | 307 | case 5: |
| 308 | /* |
| 309 | This register can be written, but if you write a 1 bit into any of |
| 310 | bits 5 - 0, you could cause an interrupt if the appropriate IER bit |
| 311 | is set. |
| 312 | */ |
| 313 | COM_LOG(1,"COM_lsr_w",("COM $%02x\n", data )); |
| 314 | |
| 315 | ins8250->lsr = data; |
| 316 | |
| 317 | switch( ins8250->lsr & 0x21 ) { |
| 318 | case 0x01: |
| 319 | ins8250_trigger_int( device, COM_INT_PENDING_RECEIVED_DATA_AVAILABLE ); |
| 320 | break; |
| 321 | case 0x20: |
| 322 | ins8250_trigger_int( device, COM_INT_PENDING_TRANSMITTER_HOLDING_REGISTER_EMPTY ); |
| 323 | break; |
| 324 | case 0x21: |
| 325 | ins8250_trigger_int( device, COM_INT_PENDING_RECEIVED_DATA_AVAILABLE | COM_INT_PENDING_TRANSMITTER_HOLDING_REGISTER_EMPTY ); |
| 326 | break; |
| 327 | } |
| 312 | 328 | break; |
| 313 | 329 | case 6: |
| 314 | 330 | break; |